* Detachable Current Head
* Dual Display  
* Non-Contact Voltage
* Work Light
* Magnet Mount
* Test Leads Storage
* Single Test Lead Holder
* Hook Separation Tab

 

 

 

 










 MAXIMA 129T Dual Display True-RMS ClampDMMT
                                                     with Detachable Current Head


  • 4000 count Dual LCD display.
  • True-RMS current measurements for testing Harmonic current flows.
  • Measures DC Voltage to 1000V, True-RMS AC Voltage to 750V and Registance to 40M目.
  • Non-Contact Voltage detecting feature.
  • AC/DC µA measurements.
  • Frequency and Duty cycle measurements.
  • Capacitance measurements.
  • Diode and Continuity Beeper tests.
  • Detachable Current Head-Compatible with all kinds of DC mV output adaptors.
  • MAX/MIN mode (Sampling rate:100ms).
  • Data Hold and Range Hold.
  • K-Type thermocouple temperature measurements.
  • Auto Power Off function.
  • Work Light.
  • Back-lit display.
  • Test leads storage.
  • Magnetic Mount.
  • 32mm jaw size.
  • IEC 1010-2-032, CATIII 600V Safety protection.
  • UL-Listed & CE-mark Certificated.

SPECIFICATIONS

AC Amps Measurement-jaw input (45 to 400Hz)
Range Resolution Accuracy Overload Protection
40A 0.01A ±2.9% + 15dgts

400A

400A 0.1A ±1.9% + 8dgts
   *45 Hz to 400 Hz True RMS(Crest factor < 3:1)
ADP Measurement
Range Resolution Accuracy Overload Protection
400mV 0.1mV ±0.5% + 4dgts 30V Max
DC micro Amps Measurement (test lead input)
Range Resolution Accuracy Overload Protection
400µA 0.01µA

±1.2% + 3dgts

2000µA

2000µA 0.1µA
AC micro Amps Measurement (test lead input, 45 to 400Hz)
Range Resolution Accuracy Overload Protection
400µA 0.01µA ±2.0% + 5dgts

2000µA

2000µA 0.1µA ±1.5% + 5dgts
   *45Hz to 1kHz True RMS (Crest factor < 3:1)
DC Volts Measurement
Range Resolution Accuracy Overload Protection
400mV 0.1mV

±0.5% + 4dgts

1000V

4V 1mV
40V 10mV
400V 100mV
1000V 1V ±0.8% + 10dgts
AC Volts Measurement (45 to 400Hz)
Range Resolution Accuracy Overload Protection
4V 1mV

±2.0% + 5dgts

750V

40V 10mV
400V 100mV
750V 1V
   *45Hz to 1kHz True RMS (Crest factor < 3:1)
Ohms Measurement
Range Resolution Accuracy Overload Protection
400目 0.1目

±1.0% + 4dgts

600V

4k目 1目
40k目 10目
400k目 100目
4M目 1k目
40M目 10k目 ±2.0% + 4dgts
Diode Test
Range Open Circuit Voltage Test Current(Typical) Overload Protection
2.0V < 3.0V DC 0.25mA 600V
Capacltance Measurement
Range Resolution Accuracy Overload Protection
40nF 0.01nF

±3.5% + 6dgts

600V

400nF 0.1nF
4µF 0.001µF
40µF 0.01µF
400µF 0.1µF
4000µF 1µF
Temperature Measurement
Range Resolution Accuracy Overload Protection
-22°F to 14°F
(-30°C to -10°C)
0.1°F
(0.1°C)
±5.4°F
(±3.0°C)

30V

15°F to 752°F
(-10°C to 400°C)
0.1°F
(0.1°C)
±1.0% + 3.6°F
(±1.0% + 2.0°C)
  Sensor: K-Type Themocouple, sensor accuracy not included.
Frequency Measurement
Range Resolution Accuracy Overload Protection
9.999Hz 0.001Hz

±0.1% + 4dgts

600V

99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 1Hz
99.99kHz 10Hz
  Minimum frequency : 0.5Hz
  Sensitivity : > 1.0 Vrms
Duty(%) Cycle Measurement
Range Accuracy Overload Protection
0.1 to 99.9% ±(0.2% per kHz + 0.1%) + 5count 600V
  0.5Hz to 100kHz (pulse width > 2µsec )
Continuity Measurement
Open circuit voltage < 2.7V Overload Protection
Threshold : Approx. < 30目 600V

 

 

The MAXIMA Series are economical, but professional, autoranging ClampDMMs and the Detachable current head system makes a MAXIMA compatible with the other manufacturer's various DC mV output adapters.
They are ideally suited for the HVAC/R and electrical maintenance professionals.
Lots of unique features and wide range of functions with high accuracy make MAXIMA Series an excellent choice for HVAC/R and electrical technicians.

 



User's Manual download


 

 

Please contact us for more information at;


FINE INSTRUMENTS CORP.

Tel : +82-31-470-8888
Fax : +82-31-470-8887
Room # 601, DAEWOO TECHNOPIA, 768-1, WONSI-DONG, DANWON-GU,
ANSAN-SI,GYEONGGI-DO, SOUTH KOREA
E-mail :  fine@finest.co.kr


 

 


 

 

Copyright(c) 2009 FINE INSTRUMENTS CORP. All rights reserved.

 

 

 

 

 

 

 

MODEL 129T