| 1006 Automotive Scope/GMM/OBD II (EOBD) Code Reader |
|
- A 25 Mega-sample/Second (one channel minimum) sample rate for rapid data updates.
- Lab scope signal patterns.
- True RMS Graphing Multimeter (GMM) measurements and graphs.
- OBD II(EOBD) Code Reader function.
- A unique "Glitch Snare" feature captures, displays and optionally saves abnormal signal patterns in the Scope mode for Component Testing.
- Preset tests enable the user to check the majority of automotive sensors, actuators and systems easily and quickly.
- Powerful built-in reference information for each preset test includes a test procedure showing how to connect to the circuit, a normal reference signal pattern, theory of operation and troubleshooting tips.
- Menu-driven interface has automatic configurations for most of non-preset tests, so you will find that the instrument is easy-to-use.
- The Secondary Ignition Single function displays the waveform along with the spark voltage, RPM, burn time and burn voltage.
- The Diesel function allows you to set injection pump timing and RPM using the optional Diesel accessories.
- Dynamic Compression Test.
- USB interface supports updates for code and data.
|
|
| SPECIFICATIONS
|
[ DSO ]
Horizontal
|
|
|
Sample rate
|
:
|
25 Mega sample/second
|
|
Record length
|
:
|
1000 Points
|
|
Update rate
|
:
|
Real time, Roll
|
|
Accuracy
|
:
|
± (0.1% + 1 pixel)
|
|
Sweep rate
|
:
|
1 µs to 50 sec in a 1, 2, 5 sequence (Scope mode) 5 s to 24 Hours in a 1, 2, 5 sequence (GMM mode)
|
Vertical
|
|
|
Band width
|
:
|
DC to 5 MHz ; -3 dB
|
|
Resolution
|
:
|
8 bit
|
|
Channel
|
:
|
2 Channel
|
|
Coupling
|
:
|
AC, DC, GND
|
|
Input Impedance
|
:
|
1 Mohm / 70 pF
|
|
Maximum Input Voltage
|
:
|
300 V
|
|
Volt/Division
|
:
|
50 mV to 100 V in a 1, 2, 5 sequence
|
|
Accuracy
|
:
|
± 3 %
|
Trigger
|
|
|
Trigger Source
|
:
|
CH A, CH B, TRIGGER (External trigger)
|
|
Sensitivity (CH A)
|
:
|
< 1.0 div to 5 MHz
|
|
Sensitivity (Trigger)
|
:
|
0.2 V p-p
|
|
Modes
|
:
|
Single shot, Normal, Auto
|
|
Coupling
|
:
|
AC, DC
|
|
Slope
|
:
|
Rising and falling edge
|
Others
|
|
|
Glitch Snare
|
:
|
SCOPE Mode (Component Test only)
|
|
Acquire Mode
|
:
|
SCOPE Mode
|
|
Setup memory
|
:
|
8 Waveform & Setup
|
|
Reference waveform
|
:
|
51 Waveform and Setup
|
|
Cursor
|
:
|
Time and Volt
|
|
Instrument Setup
|
:
|
Language, Contrast, Graticule
|
|
[ GMM ]
|
RPM Measurement
|
Mode
|
Range
|
Accuracy
|
|
4 cylinder
|
120 - 20000 RPM
|
2 RPM
|
|
2 cylinder
|
60 - 10000 RPM
|
|
Frequency Measurement
|
Function
|
Range
|
Resolution
|
Accuracy
|
|
Frequency
|
10 Hz
|
0.001 Hz
|
± (0.1 % + 3 d)
|
|
100 Hz
|
0.01 Hz
|
|
1 kHz
|
0.1 Hz
|
|
10 kHz
|
1 Hz
|
|
100 kHz
|
10 Hz
|
|
1 MHz
|
100 Hz
|
|
5 MHz
|
1 kHz
|
|
% Duty
|
2.0 % ~ 98 %
|
0.1 %
|
Pulse Width > 2 µs
|
|
Dwell
|
3.6 ° ~ 356.4 °
|
0.1 °
|
1.2 °/krpm + 2 d
|
|
Pulse Width
|
2 µs ~ 450 ms (Pulse Width > 2 µs)
|
|
DC Voltage Measurement
|
Range
|
Resolution
|
Accuracy
|
|
500 mV
|
0.1 mV
|
± (0.3 % + 5 d)
|
|
5 V
|
0.001 V
|
|
50 V
|
0.01 V
|
|
500 V
|
0.1 V
|
|
600 V
|
0.1 V
|
|
|
> Input Impedance : 10 M目
|
AC Voltage Measurement
|
Range
|
Resolution
|
Accuracy
|
|
40 Hz ~ 400 Hz
|
400 Hz ~ 10 kHz
|
|
500 mV
|
0.1 mV
|
± (0.5 % + 5 d)
|
± (2.5 % + 5 d)
|
|
5 V
|
0.001 V
|
|
50 V
|
0.01 V
|
|
500 V
|
0.1 V
|
|
600 V
|
1 V
|
|
|
> Input Impedance : 10 M目
|
(AC+DC) Voltage Measurement
|
Range
|
Resolution
|
Accuracy
|
|
40 Hz ~ 400 Hz
|
400 Hz ~ 10 kHz
|
|
DC 500 mV
|
0.1 mV
|
± (0.8 % + 5 d)
|
± (3.0 % + 5 d)
|
|
DC 5 V
|
0.001 V
|
|
DC 50 V
|
0.01 V
|
|
DC 500 V
|
0.1 V
|
|
DC 600 V
|
0.1 V
|
|
Ohm Measurement
|
Range
|
Resolution
|
Accuracy
|
|
500 目
|
0.1 目
|
± (0.5 % + 5 d)
|
|
5 k目
|
0.001 k目
|
|
50 k目
|
0.01 k目
|
|
500 k目
|
0.1 k目
|
|
5 M目
|
0.001 M目
|
± (0.75 % + 5 d)
|
|
30 M目
|
0.01 M目
|
± (0.75 % + 10 d)
|
|
Continuity Test
|
Test Voltage
|
Threshold
|
Response time
|
|
1.2 V
|
Approx. 70 目
|
1 ms
|
|
Diode Test
|
Range
|
Open Circuit Voltage
|
Accuracy
|
|
2.0 V
|
3.0 V
|
± (2.0 % + 5 d)
|
|
Temperature Measurement
|
Range
|
Resolution
|
Accuracy
|
|
-50 °C to 1300 °C
|
0.1 °C
|
± 3 °C
|
|
-58 °F to 2372 °F
|
0.1 °F
|
± 5.4 °F
|
|
DC Ampere Measurement (Current Probe Output)
|
Range
|
Resolution
|
Accuracy
|
|
30 mA ~ 20 A
|
1 mV/10 mA
|
± (1.5 % + 20 mA)
|
|
100 mA ~ 40 A
|
1 mV/100 mA
|
± (2.0 % + 20 mA)
|
|
40 A ~ 60 A
|
1 mV/100 mA
|
± (4.0 % + 0.3 A)
|
|
AC Ampere Measurement (Current Probe Output)
|
Range
|
Resolution
|
Accuracy
|
|
40 Hz ~ 1 kHz
|
1 kHz ~ 5 kHz
|
|
30 mA ~ 10 A
|
1 mV/10 mA
|
± (2.0 % + 20 mA)
|
± (4.0 % + 30 mA)
|
|
100 mA ~ 40 A
|
1 mV/100 mA
|
± (2.0 % + 20 mA)
|
± (6.0 % + 30 mA)
|
|
40 A ~ 60 A
|
1 mV/100 mA
|
± (8.0 % + 0.3 A)
|
|
|
| 
|
|
Automotive On-board diagnostic systems of thesedays have gone a long way toward helping you locate a problem. But those systems aren't perfect and they don't cover everything (most glitches and intermittents). So the real challenge that befuddles most automotive technicians is diagnosing "no-code" trouble. On-board diagnostic systems are engineered with fairly wide set limits for sensors, actuators, connectors and terminals. When a component exceeds its limit consistently, a trouble code is generated. But to keep warranty costs in line, tolerances aren't set to catch all transients, even though they can cause some of your worst headaches. As a result, technicians are finding more and more uses for the oscilloscope - next to the multimeter, the most common troubleshooting tool.
The 1006 Automotive Scope/GMM/OBD II Code Reader represents the most powerful and versatile tool available for troubleshooting automotive electronics since we can track down elusive no-code driveability problems as well as diagnose OBD II sensors and components.
|
|
|
|
User's Manual download |  |
|
|
|
Please
contact us for more information at; |
|
FINE INSTRUMENTS CORP.
Tel : +82-31-470-8888
Fax : +82-31-470-8887
Room # 601, DAEWOO TECHNOPIA, 768-1, WONSI-DONG, DANWON-GU, ANSAN-SI,
GYEONGGI-DO, SOUTH KOREA
E-mail : fine@finest.co.kr
|
|